// CODE SNIPPET
1910.120(c) Site Characterization and Analysis
Go To Full Code Chapter
1910.120(c)(1) General
Hazardous waste sites shall be evaluated in accordance with this paragraph to identify specific site hazards and to determine the appropriate safety and health control procedures needed to protect employees from the identified hazards.
1910.120(c)(2) Preliminary Evaluation
A preliminary evaluation of a site's characteristics shall be performed prior to site entry by a qualified person in order to aid in the selection of appropriate employee protection methods prior to site entry. Immediately after initial site entry, a more detailed evaluation of the site's specific characteristics shall be performed by a qualified person in order to further identify existing site hazards and to further aid in the selection of the appropriate engineering controls and personal protective equipment for the tasks to be performed.
1910.120(c)(3) Hazard Identification
All suspected conditions that may pose inhalation or skin absorption hazards that are immediately dangerous to life or health (IDLH) or other conditions that may cause death or serious harm shall be identified during the preliminary survey and evaluated during the detailed survey. Examples of such hazards include, but are not limited to, confined space entry, potentially explosive or flammable situations, visible vapor clouds, or areas where biological indicators such as dead animals or vegetation are located.
1910.120(c)(4) Required Information
The following information to the extent available shall be obtained by the employer prior to allowing employees to enter a site:
1910.120(c)(4)(i)
Location and approximate size of the site.
1910.120(c)(4)(iii)
Duration of the planned employee activity.
1910.120(c)(4)(iv)
Site topography and accessibility by air and roads.
1910.120(c)(4)(v)
Safety and health hazards expected at the site.
1910.120(c)(4)(vi)
Pathways for hazardous substance dispersion.
1910.120(c)(4)(vii)
Present status and capabilities of emergency response teams that would provide assistance to on-site employees at the time of an emergency.
1910.120(c)(4)(viii)
Hazardous substances and health hazards involved or expected at the site and their chemical and physical properties.
1910.120(c)(4)(ii)
Description of the response activity and/or the job task to be performed.
1910.120(c)(5) Personal Protective Equipment
Personal protective equipment (PPE) shall be provided and used during initial site entry in accordance with the following requirements:
1910.120(c)(5)(i)
Based upon the results of the preliminary site evaluation, an ensemble of PPE shall be selected and used during initial site entry which will provide protection to a level of exposure below permissible exposure limits and published exposure levels for known or suspected hazardous substances and health hazards and which will provide protection against other known and suspected hazards identified during the preliminary site evaluation. If there is no permissible exposure limit or published exposure level, the employer may use other published studies and information as a guide to appropriate personal protective equipment.
1910.120(c)(5)(iii)
If the preliminary site evaluation does not produce sufficient information to identify the hazards or suspected hazards of the site an ensemble providing equivalent to Level B PPE shall be provided as minimum protection, and direct reading instruments shall be used as appropriate for identifying IDLH conditions. (See Appendix B for guidelines on Level B protective equipment.)
1910.120(c)(5)(iv)
Once the hazards of the site have been identified, the appropriate PPE shall be selected and used in accordance with paragraph (g) of this section.
1910.120(c)(5)(ii)
If positive-pressure self-contained breathing apparatus is not used as part of the entry ensemble, and if respiratory protection is warranted by the potential hazards identified during the preliminary site evaluation, an escape self-contained breathing apparatus of at least five minute's duration shall be carried by employees during initial site entry.
1910.120(c)(6) Monitoring
The following monitoring shall be conducted during initial site entry when the site evaluation produces information which shows the potential for ionizing radiation or IDLH conditions, or when the site information is not sufficient reasonably to eliminate these possible conditions:
1910.120(c)(6)(i)
Monitoring with direct reading instruments for hazardous levels of ionizing radiation.
1910.120(c)(6)(iii)
Visually observing for signs of actual or potential IDLH or other dangerous conditions.
1910.120(c)(6)(iv)
An ongoing air monitoring program in accordance with paragraph (h) of this section shall be implemented after site characterization has determined the site is safe for the start-up of operations.
1910.120(c)(6)(ii)
Monitoring the air with appropriate direct reading test equipment for (i.e., combustible gas meters, detector tubes) for IDLH and other conditions that may cause death or serious harm (combustible or explosive atmospheres, oxygen deficiency, toxic substances.)
1910.120(c)(7) Risk Identification
Once the presence and concentrations of specific hazardous substances and health hazards have been established, the risks associated with these substances shall be identified. Employees who will be working on the site shall be informed of any risks that have been identified. In situations covered by the Hazard Communication Standard, 29 CFR 1910.1200, training required by that standard need not be duplicated.
NOTE TO PARAGRAPH (c)(7). - Risks to consider include, but are not limited to:
NOTE TO PARAGRAPH (c)(7). - Risks to consider include, but are not limited to:
- Exposures exceeding the permissible exposure limits and published exposure levels.
- IDLH Concentrations.
- Potential Skin Absorption and Irritation Sources.
- Potential Eye Irritation Sources.
- Explosion Sensitivity and Flammability Ranges.
- Oxygen deficiency.
1910.120(c)(8) Employee Notification
Any information concerning the chemical, physical, and toxicologic properties of each substance known or expected to be present on site that is available to the employer and relevant to the duties an employee is expected to perform shall be made available to the affected employees prior to the commencement of their work activities. The employer may utilize information developed for the hazard communication standard for this purpose.
Upcodes Diagrams
Related Code Sections
1910.120(c) Hazardous Materials, Site Characterization and Analysis
) of this section shall be implemented after site characterization has determined the site is safe for the start-up of operations ...
1910.120(c)(3) Hazardous Materials, Hazard Identification
All suspected conditions that may pose inhalation or skin absorption hazards that are immediately dangerous to life or health (IDLH) or other ...
1910.120(c)(7) Hazardous Materials, Risk Identification
with these substances shall be identified. Employees who will be working on the site shall be informed of any risks that have been identified. In situations covered ...
1910.120(c)(8) Hazardous Materials, Employee Notification
Any information concerning the chemical, physical, and toxicologic properties of each substance known or expected to be present on site ...
1910.120(c)(6)(iv) Hazardous Materials,
An ongoing air monitoring program in accordance with paragraph (h) of this section shall be implemented after site characterization has determined ...