1021.2.3 Single-Story or Multiple-Story Dwelling Units
Go To Full Code Chapter
Individual single-story or multiple-story dwelling units shall be permitted to have a single exit within and from the dwelling unit provided that all of the following criteria are met:
- The dwelling unit complies with Section 1015.1 as a space with one means of egress and
- Either the exit from the dwelling unit discharges directly to the exterior at the level of exit discharge, or the exit access outside the dwelling unit's entrance door provides access to not less than two approved independent exits.