917.1 Single-Stack Vent System Permitted
Go To Full Code Chapter
A drainage stack shall serve as a single-stack vent system where sized and installed in accordance with Sections 917.2 through 917.9. The drainage stack and branch piping shall be the vents for the drainage system. The drainage stack shall have a stack vent.
Related Code Sections
917.1 Vents, Single-Stack Vent System Permitted
A drainage stack shall serve as a single-stack vent system where sized and installed in accordance with Sections 917.2 through 917.9. The drainage ...
917.1 Vents, Where Permitted
A drainage stack shall serve as a single stack vent system where sized and installed in accordance with Sections 917.2 through 917.9. The drainage ...
Section P3102 Vents, Vent Stacks and Stack Vents
The vent system serving each building drain shall have not less than one vent pipe that extends to the outdoors ...
Section 917 Vents, Single Stack Vent System
A drainage stack shall serve as a single stack vent system where sized and installed in accordance with Sections 917.2 through 917.9. The drainage ...
917.3.3 Vents, Stack
Stack-type air admittance valves shall not serve as the vent terminal for vent stacks or stack vents that serve drainage stacks having more than six ...