// CODE SNIPPET
1926.452(o) "Single-Point Adjustable Suspension Scaffolds"
Go To Full Code Chapter
1926.452(o)(1)
When two single-point adjustable suspension scaffolds are combined to form a two-point adjustable suspension scaffold, the resulting two-point scaffold shall comply with the requirements for two-point adjustable suspension scaffolds in paragraph (p) of this section.
1926.452(o)(2)
The supporting rope between the scaffold and the suspension device shall be kept vertical unless all of the following conditions are met:
1926.452(o)(2)(i)
The rigging has been designed by a qualified person, and
1926.452(o)(2)(ii)
The scaffold is accessible to rescuers, and
1926.452(o)(2)(iii)
The supporting rope is protected to ensure that it will not chafe at any point where a change in direction occurs, and
1926.452(o)(2)(iv)
The scaffold is positioned so that swinging cannot bring the scaffold into contact with another surface.
1926.452(o)(3)
Boatswains' chair tackle shall consist of correct size ball bearings or bushed blocks containing safety hooks and properly "eye-spliced" minimum five-eighth (5/8) inch (1.6 cm) diameter first-grade manila rope, or other rope which will satisfy the criteria (e.g., strength and durability) of manila rope.
1926.452(o)(4)
Boatswains' chair seat slings shall be reeved through four corner holes in the seat; shall cross each other on the underside of the seat; and shall be rigged so as to prevent slippage which could cause an out-of-level condition.
1926.452(o)(5)
Boatswains' chair seat slings shall be a minimum of five-eight (5/8) inch (1.6 cm) diameter fiber, synthetic, or other rope which will satisfy the criteria (e.g., strength, slip resistance, durability, etc.) of first grade manila rope.
1926.452(o)(6)
When a heat-producing process such as gas or arc welding is being conducted, boatswains' chair seat slings shall be a minimum of three-eight (3/8) inch (1.0 cm) wire rope.
1926.452(o)(7)
Non-cross-laminated wood boatswains' chairs shall be reinforced on their underside by cleats securely fastened to prevent the board from splitting.
Upcodes Diagrams
Related Code Sections
1926.452(o) Scaffolds, "Single-Point Adjustable Suspension Scaffolds"
When two single-point adjustable suspension scaffolds are combined to form a two-point adjustable suspension scaffold, the resulting two-point ...
1926.452(o)(2)(iv) Scaffolds,
The scaffold is positioned so that swinging cannot bring the scaffold into contact with another surface ...
1926.452(o)(3) Scaffolds,
Boatswains' chair tackle shall consist of correct size ball bearings or bushed blocks containing safety hooks and properly "eye-spliced" minimum five ...
1926.452(o)(4) Scaffolds,
Boatswains' chair seat slings shall be reeved through four corner holes in the seat; shall cross each other on the underside of the seat; and shall ...
1926.452(o)(5) Scaffolds,
Boatswains' chair seat slings shall be a minimum of five-eight (5/8) inch (1.6 cm) diameter fiber, synthetic, or other rope which will satisfy ...