R602.7.1 Single Member Headers
JUMP TO FULL CODE CHAPTER


Single headers shall be framed with a single flat 2-inch-nominal (51 mm) member or wall plate not less in width than the wall studs on the top and bottom of the header in accordance with Figures R602.7.1(1) and R602.7.1(2) and face nailed to the top and bottom of the header with 10d box nails (3 inches × 0.128 inches) spaced 12 inches on center.
SINGLE MEMBER HEADER IN EXTERIOR BEARING WALL
ALTERNATIVE SINGLE MEMBER HEADER WITHOUT CRIPPLE
Related Code Sections
R602.7.1 Wall Construction, Single Member Headers
Single headers shall be framed with a single flat 2-inch-nominal (51 mm) member or wall plate not less in width than the wall studs on the top ...
Los Angeles Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.7 Headers > R602.7.1 Single Member Headers
R602.7.1 Wall Construction, Single Member Headers
Single headers shall be framed with a single flat 2-inch-nominal (51 mm) member or wall plate not less in width than the wall studs on the top ...
Los Angeles Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.7 Headers > R602.7.1 Single Member Headers
2308.5.5.1 Wood, Openings in Exterior Bearing Walls
with Table 2304.10.1 or of solid lumber of equivalent size. Single-member headers of nominal 2-inch (51 mm) thickness shall be framed with a single flat 2 ...
Los Angeles Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.5 Openings in Walls and Partitions > 2308.5.5.1 Openings in Exterior Bearing Walls
R502.10 Floors, Framing of Openings
joist shall be a single member the same size as the floor joist. Single trimmer joists shall be used to carry a single header joist that is located ...
R502.10 Floors, Framing of Openings
joist shall be a single member the same size as the floor joist. Single trimmer joists shall be used to carry a single header joist that is located ...