1616.6.1 Simplified Analysis
Go To Full Code Chapter
A simplified analysis, in accordance with Section 1617.5, shall be permitted to be used for any structure in Seismic Use Group I, subject to the following limitations, or a more rigorous analysis shall be made:
- Buildings of light-framed construction not exceeding three stories in height, excluding basements.
- Buildings of any construction other than light-framed construction, not exceeding two stories in height, excluding basements, with flexible diaphragms at every level as defined in Section 1602.
Upcodes Diagrams
Related Code Sections
1616.6.1 Structural Design, Simplified Analysis
A simplified analysis, in accordance with Section 1617.5, shall be permitted to be used for any structure in Seismic Use Group I, subject ...
1617.5 Structural Design, Simplified Analysis Procedure for Seismic Design of Buildings
be taken as 1 percent of the story height unless a more exact analysis is provided ...
1620.2 Structural Design, Structural Component Design and Detailing (For Use in the Simplified Analysis Procedure of Section 1617.5)
The design and detailing of the components of the seismic-force-resisting system for structures designed using the simplified analysis procedure ...
1617.5.1 Structural Design, Seismic Base Shear
The seismic base shear, V, in a given direction shall be determined in accordance with the following equation:
V = (1.2SDS / R)W ...
1617.5.2 Structural Design, Vertical Distribution
The forces at each level shall be calculated using the following equation:
Fx = (1.2 SDS / R)wx