AS105.3 Sill Plates
Go To Full Code Chapter
Sill plates shall be installed in accordance with Figure AS105.1(1) or AS105.1(2). Sill plates shall support and be flush with each face of the straw bales above and shall be of naturally durable or preservative-treated wood where required by this code. Sill plates shall be not less than nominal 2 inches by 4 inches (51 mm by 102 mm) with anchoring complying with Section R403.1.6 and the additional requirements of Table AS105.4, where applicable, and Sections AS106.13.2 and AS106.13.3 for strawbale braced wall panels.
AS105.3.1 Exterior Sill Plate Flashing
Exterior sill plates shall receive flashing across the plate to slab or foundation joints.