§27-391 Signs at Elevator Landings
JUMP TO FULL CODE CHAPTER
A sign shall be posted and maintained on every floor at the elevator landing. The sign shall read "IN CASE OF FIRE, USE STAIRS UNLESS OTHERWISE INSTRUCTED". The lettering shall be at least one-half inch block letters in red with white background or as otherwise approved by the commissioner. Such lettering shall be properly spaced to provide good legibility. The sign shall also contain a diagram showing the location where it is posted and the location and letter identification of the stairs on the floor. The sign shall be at least ten inches by twelve inches, located directly above a call button and securely attached to the wall or partition. The top of such sign shall not be above six feet from the floor level. The diagram on such sign may be omitted provided that signs containing such diagram are posted in conspicuous places on the respective floor. In such case, the sign at the elevator landing shall be at least two and one half inches by ten inches and the diagram signs shall be at least eight inches by twelve inches.
Related Code Sections
§27-391 Means of Egress, Signs at Elevator Landings
A sign shall be posted and maintained on every floor at the elevator landing. The sign shall read "IN CASE OF FIRE, USE STAIRS UNLESS OTHERWISE ...
NYC 1968 Code (Vol I) > 6 Means of Egress > 9 Stair and Elevator Signs > §27-391 Signs at Elevator Landings
3002.3 Elevators and Conveying Systems, Emergency Signs
A sign shall be posted and maintained on every floor at the elevator landing. The sign shall read "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE THE ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.3 Emergency Signs
3002.3 Elevators and Conveying Systems, Emergency Signs
A sign shall be posted and maintained on every floor at the elevator landing. The sign shall read "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE THE ...
NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.3 Emergency Signs
407.2.3.1 Accessible Routes, Floor Designation
(51 mm) minimum in height. Floor designations shall be located on both jambs of elevator hoistway entrances. A raised star shall be provided on both ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 4 Accessible Routes > 407 Elevators > 407.2 Elevator Landing Requirements > 407.2.3 Hoistway Signs > 407.2.3.1 Floor Designation
Appendix A Selected Rules of the Department of Buildings [PDF] (page 83)
, pursuant to §27-390 of the Administrative (Building) Code, as enacted by Local Law 16 of 1984. (b) Signs at elevator landings. (1) Elevator landing sign ...