Property on which Type 1 magazines and outdoor magazines of Types 2, 4 and 5 are located shall be posted with signs stating: "NO SMOKING" and "EXPLOSIVES—KEEP OFF." These signs shall be of contrasting colors with a minimum letter height of 3 inches (76 mm) with a minimum brush stroke of 1/2 inch (12.7 mm). The signs shall be located to minimize the possibility of a bullet shot at the sign hitting the magazine.
5604.6.5.1 Access Road Signs
At the entrance to explosive material manufacturing and storage sites, all access roads shall be posted with the following warning sign or other approved sign:
DANGER!
NEVER FIGHT EXPLOSIVE FIRES.
EXPLOSIVES ARE STORED ON THIS SITE
CALL _______
The sign shall be weather resistant with a reflective surface and have lettering not less than 2 inches (51 mm) high.
5604.6.5.2 Placards
Type 5 magazines containing Division 1.5 blasting agents shall be prominently placarded as required during transportation by DOTn 49 CFR Part 172 and DOTy 27 CFR Part 555.
Upcodes Diagrams

Related Code Sections

5604.6.5 Explosives and Fireworks, Signs and Placards
Property on which Type 1 magazines and outdoor magazines of Types 2, 4 and 5 are located shall be posted with signs stating: EXPLOSIVES—KEEP OFF ...
5604.6.5 Explosives and Fireworks, Signs and Placards
Property on which Type 1 magazines and outdoor magazines of Types 2, 4 and 5 are located shall be posted with signs stating: "NO SMOKING ...
311.2.1 General Requirements, Security
entry by unauthorized individuals. The fire code official is authorized to placard, post signs, erect barrier tape or take similar measures as necessary ...
311.2.1 General Requirements, Security
entry by unauthorized individuals. The fire code official is authorized to placard, post signs, erect barrier tape or take similar measures as necessary ...
5704.2.3.2 Flammable and Combustible Liquids, Label or Placard
, shall bear a label and placard identifying the material therein. Placards shall be in accordance with NFPA 704. Exceptions: Tanks of 300-gallon ...