• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.145(d) Sign Design

OSHA 1910 General Industry > J General Environmental Controls > 1910.145 Specifications for Accident Prevention Signs and Tags > 1910.145(d) Sign Design
JUMP TO FULL CODE CHAPTER

1910.145(d)(1) Design Features

All signs shall be furnished with rounded or blunt corners and shall be free from sharp edges, burrs, splinters, or other sharp projections. The ends or heads of bolts or other fastening devices shall be located in such a way that they do not constitute a hazard.

1910.145(d)(2) Danger Signs

The colors red, black, and white shall be those of opaque glossy samples as specified in Table 1, "Fundamental Specification of Safety Colors for CIE Standard Source 'C,' " of ANSI Z53.1-1967 or in Table 1, "Specification of the Safety Colors for CIE Illuminate C and the CIE 1931, 2° Standard Observer," of ANSI Z535.1-2006(R2011), incorporated by reference in § 1910.6.

1910.145(d)(3) [Reserved]

1910.145(d)(4) Caution Signs

The standard color of the background shall be yellow; and the panel, black with yellow letters. Any letters used against the yellow background shall be black. The colors shall be those of opaque glossy samples as specified in Table 1 of ANSI Z53.1-1967 or Table 1 of ANSI Z535.1-2006(R2011), incorporated by reference in § 1910.6.

1910.145(d)(5) [Reserved]

1910.145(d)(6) Safety Instruction Signs

The standard color of the background shall be white; and the panel, green with white letters. Any letters used against the white background shall be black. The colors shall be those of opaque glossy samples as specified in Table 1 of ANSI Z53.1-1967 or in Table 1 of ANSI Z535.1-2006(R2011), incorporated by reference in § 1910.6.

1910.145(d)(7) [Reserved]

1910.145(d)(8) [Reserved]

1910.145(d)(9) [Reserved]

1910.145(d)(10) Slow-Moving Vehicle Emblem

This emblem (see fig. J-7) consists of a fluorescent yellow-orange triangle with a dark red reflective border. The yellow-orange fluorescent triangle is a highly visible color for daylight exposure. The reflective border defines the shape of the fluorescent color in daylight and creates a hollow red triangle in the path of motor vehicle headlights at night. The emblem is intended as a unique identification for, and it shall be used only on, vehicles which by design move slowly (25 m.p.h. or less) on the public roads. The emblem is not a clearance marker for wide machinery nor is it intended to replace required lighting or marking of slow-moving vehicles. Neither the color film pattern and its dimensions nor the backing shall be altered to permit use of advertising or other markings. The material, location, mounting, etc., of the emblem shall be in accordance with the American Society of Agricultural Engineers Emblem for Identifying Slow-Moving Vehicles, ASAE R276, 1967, or ASAE S276.2 (ANSI B114.1-1971), which are incorporated by reference as specified in Sec. 1910.6.

FIGURE J-7. - SLOW-MOVING VEHICLE EMBLEM


Note: All Dimension are in inches.

Related Code Sections


1910.145(d) General Environmental Controls, Sign Design
All signs shall be furnished with rounded or blunt corners and shall be free from sharp edges, burrs, splinters, or other sharp projections. The ends ...
OSHA 1910 General Industry > J General Environmental Controls > 1910.145 Specifications for Accident Prevention Signs and Tags > 1910.145(d) Sign Design
1910.145(d)(3) General Environmental Controls, [Reserved]
OSHA 1910 General Industry > J General Environmental Controls > 1910.145 Specifications for Accident Prevention Signs and Tags > 1910.145(d) Sign Design > 1910.145(d)(3) [Reserved]
1910.145(d)(5) General Environmental Controls, [Reserved]
OSHA 1910 General Industry > J General Environmental Controls > 1910.145 Specifications for Accident Prevention Signs and Tags > 1910.145(d) Sign Design > 1910.145(d)(5) [Reserved]
1910.145(d)(7) General Environmental Controls, [Reserved]
OSHA 1910 General Industry > J General Environmental Controls > 1910.145 Specifications for Accident Prevention Signs and Tags > 1910.145(d) Sign Design > 1910.145(d)(7) [Reserved]
1910.145(d)(8) General Environmental Controls, [Reserved]
OSHA 1910 General Industry > J General Environmental Controls > 1910.145 Specifications for Accident Prevention Signs and Tags > 1910.145(d) Sign Design > 1910.145(d)(8) [Reserved]
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE