The sidewalls shall extend not less than 9 inches (229 mm) above the liquid depth. The cover of the septic tank shall be not less than 2 inches (51 mm) above the back vent openings.
Upcodes Diagrams

Related Code Sections

H 501.9 Private Sewage Disposal Systems, Sidewalls
The sidewalls shall extend not less than 9 inches (229 mm) above the liquid depth. The cover of the septic tank shall be not less than 2 inches (51 ...
H 701.6 Private Sewage Disposal Systems, Sidewall
A seepage pit shall have a minimum sidewall (not including the arch) of 10 feet (3048 mm) below the inlet ...
3.6.2.5 Definitions, Sidewall Sprinkler
A sprinkler having special deflectors that are designed to discharge most of the water away from the nearby wall in a pattern resembling one-quarter ...
R905.2.8.3 Roof Assemblies, Sidewall Flashing
Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches ...