• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3111 Sidewalk Cafés

NYC Building Code 2014 > 31 Special Construction > 3111 Sidewalk Cafés
JUMP TO FULL CODE CHAPTER

*3111.1 General

Sidewalk cafés provided beyond the buildingline shall comply with the requirements of this section, the New York City Zoning Resolution, the Commissioners of the Department of Consumer and Worker Protectionand Department of Transportation, and with the projection limitations of Chapter 32 of this code.
*Section 3111.1 was amended by Local Law 80 of 2020. This law has an effective date of August 28, 2020.

3111.2 Enclosures

Enclosed sidewalk cafés shall be constructed of noncombustible material. The walls of such enclosures shall not extend more than 8 feet (2438 mm) above the sidewalk. Light-transmitting plastic glazing complying with Section 2606 shall be permitted as glazing within such walls. Light-transmitting plastic skylight glazing complying with Section 2610 may be installed in the roofs of such enclosures.

3111.3* Awnings

Awnings supported entirely from the building may be placed over unenclosed sidewalk cafés provided they are at least 8 feet (2438 mm) clear above the sidewalk and within the limits specified by the Commissioner of the Department of Consumer and Worker Protection. Such awnings shall be in compliance with Section 3105 of this code.
*Section 3111.3 was amended by Local Law 80 of 2020. This law has an effective date of August 28, 2020.

3111.4 Obstructions Prohibited

No part of any awning, enclosure, fixture, equipment or removable platform of a sidewalk café shall be located:
  1. Beneath a fire escape so as to obstruct operation of fire escape drop ladders or counter-balanced stairs;
  2. So as to obstruct any exit from a building;
  3. So as to obstruct any cellar access hatch or areaway;
  4. So as to interfere with any vent or other mechanical ventilation outlet or inlet;
  5. So as to interfere with or obscure any standpipe connections, hydrant or associated signage in any way that would hinder its use by the Fire Department.
Exception: Upon special application, the commissioner may permit an easily removable, prominently designated platform, designed in accordance with Section 3111.5, to cover a cellar entrance or areaway that is not used as a required means of egress.

3111.5 Removable Platforms

Removable platforms of sidewalk cafés shall be constructed in accordance with the requirements of this section.

3111.5.1 Continuity

Removable platforms shall be constructed to provide for a continuous unbroken and level floor without openings or cracks so as to prevent any material or liquid from falling through to the area beneath.

3111.5.2 Maintenance

No papers, trash or other materials may be permitted to accumulate in the area beneath the floor of any removable platform.

3111.6 Accessibility

Sidewalk cafés and access thereto shall comply with Chapter 11.

3111.7 Assembly Seating

Unless separated from seating inside the building by fire partitions complying with Section 708, the seating for enclosed sidewalk cafés shall be added to that inside the building in order to determine whether a place of assembly certificate of operation is required.

3111.8 Rules

In addition to the requirements specified herein, the commissioner may promulgate such additional rules necessary to secure safety.

Related Code Sections


*3202.3.1 Encroachments Into the Public Right-Of-Way, Sidewalk Cafés
Enclosures for sidewalk cafés, where permitted by the Commissioner of the Department of Consumer Affairs pursuant to applicable law and constructed ...
NYC Building Code 2022 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.3 Temporary Encroachments > *3202.3.1 Sidewalk Cafés
*3202.4.1 Encroachments Into the Public Right-Of-Way, Sidewalk Cafés
Enclosures for sidewalk cafés, where permitted by the Commissioner of the Department of Consumer and Worker Protection pursuant to applicable law ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.4 Temporary Encroachments > *3202.4.1 Sidewalk Cafés
Section 3110 Special Construction, Sidewalk Cafés
Sidewalk cafés provided beyond the building line shall comply with the requirements of this section, the New York City Zoning Resolution ...
NYC Building Code 2008 > 31 Special Construction > 3110 Sidewalk Cafés
Section 3111 Special Construction, Sidewalk Cafés
Sidewalk cafés provided beyond the buildingline shall comply with the requirements of this section, the New York City Zoning Resolution ...
NYC Building Code 2014 > 31 Special Construction > 3111 Sidewalk Cafés
Section 3111 Special Construction, Sidewalk Cafés
Sidewalk cafés provided beyond the building line shall comply with the requirements of this section, the New York City Zoning Resolution ...
NYC Building Code 2022 > 31 Special Construction > 3111 Sidewalk Cafés
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING