Where provided, curb ramp flares shall not be steeper than 1:10.
Figure 406.3 Sides of Curb Ramps
A curb ramp with triangular flared sides is shown.  The flared sides have a maximum 1:10 slope, measured at the curb face.
Upcodes Diagrams

Related Code Sections

406.3 Accessible Routes, Sides of Curb Ramps
Where provided, curb ramp flares shall not be steeper than 1:10. Figure 406.3 Sides of Curb Ramps ...
402.2 Accessible Routes, Components
, ramps, curb ramps excluding the flared sides, elevators, and platform lifts.  All components of an accessible route shall comply ...
402 Accessible Routes, Accessible Routes
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ...
405.9 Accessible Routes, Edge Protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS ...
(i) 28 CFR 35.151 New Construction and Alterations, Curb Ramps
Newly constructed or altered streets, roads, and highways must contain curb ramps or other sloped areas at any intersection having curbs or other ...