1002.4.4.2 Side Entry
Go To Full Code Chapter
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to enter and exit the ride.
Advisory 1002.4.4.2 Side Entry. The amount of clear space needed within the ride, and the size and position of the opening are interrelated. A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride. Additional space for maneuvering and a wider door will be needed where a side opening is centered on the ride. For example, where a 42 inch (1065 mm) opening is provided, a minimum clear space of 60 inches (1525 mm) in length and 36 inches (915mm) in depth is needed to ensure adequate space for maneuvering.
Related Code Sections
1002.4.4.2 Recreation Facilities, Side Entry
using a wheelchair or mobility aid to enter and exit the ride. Advisory 1002.4.4.2 Side Entry. The amount of clear space needed within the ride ...
608.2.3 Plumbing Elements and Facilities, Alternate Roll-in Type Shower Compartments
at center points of opposing sides. A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment ...
608.2.2 Plumbing Elements and Facilities, Standard Roll-in Type Shower Compartments
measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment ...
608.2.1 Plumbing Elements and Facilities, Transfer Type Shower Compartments
sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower compartment. Clearance of 36 inches (915 mm) wide minimum ...
404.2.4 Accessible Routes, Maneuvering Clearances
and the required latch side or hinge side clearance.
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide ...