Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry.  Where a seat is provided in an alternate roll-in type shower compartment, it shall be a folding type, shall be installed on the front wall opposite the back wall, and shall extend from the adjacent side wall to a point within 3 inches (75 mm) of the compartment entry.  In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry.  The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor.  Seats shall comply with 610.3.1 or 610.3.2.
Figure 610.3 Extent of Seat
Figure (a) is a plan view of a rectangular seat and figure (b) is a plan view of an L-shaped seat.  The front edge of each is 3 inches (75 mm) maximum from the compartment entry.
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 21/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall.  The side edge of the seat shall be 11/2 inches (38 mm) maximum from the adjacent wall.
Figure 610.3.1 Rectangular Shower Seat
610.3.2 L-Shaped Seats
The rear edge of an L-shaped seat shall be 21/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall.  The rear edge of the "L" portion of the seat shall be 11/2 inches (38 mm) maximum from the wall and the front edge shall be 14 inches (355 mm) minimum and 15 inches (380 mm) maximum from the wall.  The end of the "L" shall be 22 inches (560 mm) minimum and 23 inches maximum (585 mm) from the main seat wall.
Figure 610.3.2 L-Shaped Shower Seat

Related Code Sections

610.3 Plumbing Elements and Facilities, Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent ...
608.4 Plumbing Elements and Facilities, Seats
A folding or non-folding seat shall be provided in transfer type shower compartments. A folding seat shall be provided in roll-in type showers ...
608.5.1 Plumbing Elements and Facilities, Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches ...
610 Plumbing Elements and Facilities, Seats
Seats in bathtubs and shower compartments shall comply with 610 ...
608.3.2 Plumbing Elements and Facilities, Standard Roll-in Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite ...