• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(e) 5614.1.5 Shipping Into Ohio

2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks > 5614 Fireworks Categories and Labeling > 5614.1 > 5614.1.5 Shipping Into Ohio
JUMP TO FULL CODE CHAPTER
Only the following categories of fireworks may be shipped into Ohio:

(i) 5614.1.5.1 Directly to a Licensed Manufacturer or a Licensed Wholesaler

1.1G fireworks (UN0333), 1.2G fireworks (UN0334), 1.3G fireworks (UN0335), 1.4G fireworks (UN0336), 1.4G special effects fireworks (UN0431), 1.4S fireworks (UN0337) or 1.4S special effects fireworks (UN0432).

(ii) 5614.1.5.2 Directly to a Licensed Exhibitor at the Site of a Properly Permitted Outdoor Exhibition for Such Exhibitor

1.1G fireworks (UN0333), 1.2G fireworks (UN0334), 1.3G fireworks (UN0335), 1.4G fireworks (UN0336), 1.4G special effects fireworks (UN0431), 1.4S fireworks (UN0337) or 1.4S special effects fireworks (UN0432).

(iii) 5614.1.5.3 Directly to a Licensed Exhibitor at the Site of a Properly Permitted Indoor Exhibition for Such Exhibitor

1.4G special effects fireworks (UN0431), 1.4S fireworks (UN0337) or 1.4S special effects fireworks (UN0432).
All such shipments must be in accordance with federal laws, rules and regulations, Chapter 3743. of the Revised Code, this rule and the applicable provisions of NFPA 1123, NFPA 1124 and/or NFPA 1126 as listed in rule 1301:7-7-80 of the Administrative Code.

Related Code Sections


3314.1.5 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Shipping Into Ohio
Only the following categories of fireworks may be shipped into Ohio ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3314 Fireworks Categories and Labeling > 3314.1 > 3314.1.5 Shipping Into Ohio
5614.1.5 Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks, Shipping Into Ohio
Only the following categories of fireworks may be shipped into Ohio ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks > 5614 Fireworks Categories and Labeling > 5614.1 > 5614.1.5 Shipping Into Ohio
5614.1.5.3 Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks, Directly to a Licensed Exhibitor at the Site of a Properly Permitted Indoor Exhibition for Such Exhibitor
1.4G special effects fireworks (UN0431), 1.4S fireworks (UN0337) or 1.4S special effects fireworks (UN0432). All such shipments must ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks > 5614 Fireworks Categories and Labeling > 5614.1 > 5614.1.5 Shipping Into Ohio > 5614.1.5.3 Directly to a Licensed Exhibitor at the Site of a Properly Permitted Indoor Exhibition for Such Exhibitor
Section 3309 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Shipping and Transportation
in this state and all wholesale and commercial sales of fireworks shall be packaged, shipped, placarded, and transported in accordance with DOTn ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3309 Shipping and Transportation
Section 5609 Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks, Shipping and Transportation
in this state and all wholesale and commercial sales of fireworks shall be packaged, shipped, placarded, and transported in accordance with DOTn ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks > 5609 Shipping and Transportation
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING