Sheet lead shall weigh not less than indicated for the following applications:
  1. Flashing of vent terminals, 3 psf (15 kg/m2).
  2. Prefabricated flashing for vent pipes, 21/2 psf (12 kg/m2).

Related Code Sections

402.4 Fixtures, Faucets and Fixture Fittings, Sheet Lead
Sheet lead for pans shall not weigh less than 4 pounds per square foot (19.5 kg/m2) and shall be coated with an asphalt paint or other approved ...
421.5.2.3 Fixtures, Faucets and Fixture Fittings, Sheet Lead
Sheet lead shall weigh not less than 4 pounds per square foot (19.5 kg/m2) and shall be coated with an asphalt paint or other approved coating. The ...
902.3 Vents, Sheet Lead
Sheet lead for vent pipe flashings shall weigh not less than 3 pounds per square foot (15 kg/m2) for field-constructed flashings and not less than 21 ...
P3002.4.1 Sanitary Drainage, Sheet Lead
Sheet lead shall weigh not less than indicated for the following applications: Flashing of vent terminals, 3 psf (15 kg/m2). Prefabricated ...