Minimum nominal thickness of masonry shear walls shall be 8 inches (203 mm).
  Exception: Shear walls of one-story buildings are permitted to be a minimum nominal thickness of 6 inches (152 mm).
Upcodes Diagrams

Related Code Sections

2109.2.1.1 Masonry, Shear Wall Thickness
Minimum nominal thickness of masonry shear walls shall be 8 inches (203 mm).   Exception: Shear walls of one-story buildings ...
11.5.4.2 Walls,
For in-plane shear design, h is thickness of wall and d shall be taken equal to 0.8ℓw. A larger value of d, equal to the distance from extreme ...
2211.4.4 Steel, Sheet Steel Sheathing
of this section. Perimeter members at openings shall be provided and shall be detailed to distribute the shearing stresses. Wall studs and track shall ...
2305.3 Wood, Shear Wall Deflection
The deflection (A) of a blocked wood structural panel shear wall uniformly fastened throughout with staples is permitted to be calculated by the use ...
2306.5 Wood, Particleboard Shear Walls
2306.5 ALLOWABLE SHEAR FOR PARTICLE BOARD SHEAR WALL SHEATHINGb PANEL GRADE MINIMUM NOMINAL PANEL THICKNESS (inch) MINIMUM NAIL ...