A509.1.2.3 Shear Strength Limitation
Go To Full Code Chapter
The required in-plane shear strength of all columns, piers and shear walls shall be the shear associated with the moments induced at the ends of columns or piers and at the base of shear walls by the story displacements. No strength reduction factors shall be used in the determination of strength.
Upcodes Diagrams
Related Code Sections
A509.1.2.3 Earthquake Hazard Reduction in Existing Concrete Buildings and Concrete With Masonry Infill Buildings, Shear Strength Limitation
The required in-plane shear strength of all columns, piers and shear walls shall be the shear associated with the moments induced at the ends ...
22.6.3.1 Sectional Strength,
The value of used to calculate vc for two-way shear shall not exceed 100 psi ...
22.5.3.1 Sectional Strength,
The value of used to calculate Vc, Vci, and Vcw for one-way shear shall not exceed 100 psi, unless allowed in 22.5.3.2 ...
22.9.4.4 Sectional Strength,
The value of Vn across the assumed shear plane shall not exceed the limits in Table 22.9.4.4. Where concretes of different strengths are cast against ...
22.9.1 Sectional Strength, General
be calculated in accordance with 22.9.4. Alternatively, it shall be permitted to use shear transfer design methods that result in prediction of strength ...