3104F.4.5 Shear Key Forces
Go To Full Code Chapter
Shear force across shear keys connecting adjacent wharf segments, Vsk, (approximate upper bound to the shear key force [4.7]) shall be calculated as follows:

(4-22)
VΔT = total segment lateral force found from a pushover analysis
Ll = segment length
e = eccentricity between the center of rigidity and the center of mass
Upcodes Diagrams