Where shallow foundations are supported at different levels, or are at different levels from the shallow foundations of adjacent structures, the influence of the pressures under the higher foundation on the stability of the lower foundations shall be considered in the design. The design shall consider the requirements for lateral support of the material supporting the higher foundation, the additional load imposed on the lower foundations, and assessment of the effects of dragdown on deep foundations supporting adjacent buildings or compression of soils supporting adjacent buildings.

Related Code Sections

1805.4 Soils and Foundations, Shallow Foundations at Different Levels
Where shallow foundations are supported at different levels, or are at different levels from the shallow foundations of adjacent structures ...
1809.4 Soils and Foundations, Shallow Foundations at Different Levels
Where shallow foundations are supported at different levels, or are at different levels from the shallow foundations of adjacent structures ...
13.3 Foundations, Shallow Foundations
design and detailing of one-way shallow foundations, including strip footings, combined footings, and grade beams, shall be in accordance ...
1809.5.7.6 Soils and Foundations, Dewatering
Where piers are carried to depths below the groundwater level, the piers shall be constructed by a method that will provide accurate preparation ...
1805.5.7 Soils and Foundations, Pier Foundations
The design, materials, and construction of pier foundations shall conform to the requirements of Sections 1805.5.2, 1805.5.3, and 1805.5.7.1 through ...