• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

106.6 Sewer Adequacy Verification

NYC Plumbing Code 2008 > 1 Administration > 106 Construction Documents > 106.6 Sewer Adequacy Verification
JUMP TO FULL CODE CHAPTER
Applications for construction document approval shall include a house/site connection application approved or accepted by the Department of Environmental Protection as to the availability of a public sewer system, and when not available, alternate provisions for disposal of storm water and sanitary sewerage.

106.6.1 Increases in Existing Impervious Surfaces

buildings bulletin
Linked Resources Available

This section has been clarified by a buildings bulletin issued by the Department of Buildings.

Learn more in the Linked Resources panel on the right.
Whenever an alteration increases impervious surfaces on the lot to greater than 20 percent of the impervious surfaces existing when the structure was constructed, the applicant shall submit a house/site connection application approved or accepted by the Department of Environmental Protection as to the availability of a public sewer system, as well as an evaluation of the adequacy of any existing system for the disposal of storm water by any means other than storm or combined sewers.
  Exception: Where the total area of impervious surfaces proposed to be increased by an alteration after the effective date of this code is less than or equal to 1,000 square feet (93 m2).

Related Code Sections


106.6 Administration, Sewer Adequacy Verification
system, as well as an evaluation of the adequacy of any existing system for the disposal of storm water by any means other than storm or combined sewers ...
NYC Plumbing Code 2008 > 1 Administration > 106 Construction Documents > 106.6 Sewer Adequacy Verification
106.11 Administration, Sewer Adequacy Verification for Increases in Impervious Surfaces
as to the availability of a public sewer system, as well as an evaluation of the adequacy of any existing system for the disposal of storm water by any ...
NYC Building Code 2008 > 1 Administration > 106 Construction Documents > 106.11 Sewer Adequacy Verification for Increases in Impervious Surfaces
§27-848.05 Heating and Combustion Equipment, Structural Adequacy
as to the adequacy of the structural supports and chimney bracing to sustain the loadings when in operation ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 19 Solid Fuel Fireplaces, Fireplace Stoves and Room Heaters > §27-848.05 Structural Adequacy
1114.5.3 Storm Drainage, Verification
The department reserves the right to require a 24-hour test to verify the absorption of water in the installed on-site stormwater disposal system ...
NYC Plumbing Code 2014 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation > 1114.5.3 Verification
1114.5.3 Storm Drainage, Verification
The department reserves the right to require a 24-hour test to verify the absorption of water in the installed on-site stormwater disposal system ...
NYC Plumbing Code 2022 > 11 Storm Drainage > 1114 Private On-Site Stormwater Disposal Systems > 1114.5 On-Site Stormwater Disposal System Installation > 1114.5.3 Verification
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING