• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[P] 2903.1 Setting

Building Code 2021 of Illinois > 29 Plumbing Systems > 2903 Installation of Fixtures > 2903.1 Setting
JUMP TO FULL CODE CHAPTER
Fixtures shall be set level and in proper alignment with reference to adjacent walls.

[P] 2903.1.1 Water Closets, Urinals, Lavatories and Bidets

A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to any side wall, partition, vanity or other obstruction. Where partitions or other obstructions do not separate adjacent fixtures, fixtures shall not be set closer than 30 inches (762 mm) center to center between adjacent fixtures. There shall be not less than a 21-inch (533 mm) clearance in front of a water closet, urinal, lavatory or bidet to any wall, fixture or door. Water closet compartments shall be not less than 30 inches (762 mm) in width and not less than 60 inches (1524 mm) in depth for floor-mounted water closets and not less than 30 inches (762 mm) in width and 56 inches (1422 mm) in depth for wall-hung water closets.
Exception: An accessible children's water closet shall be set not closer than 12 inches (305 mm) from its center to the required partition or to the wall on one side.

[P] 2903.1.2 Public Lavatories

In employee and public toilet rooms, the required lavatory shall be located in the same room as the required water closet.

[P] 2903.1.3 Location of Fixtures and Piping

Piping, fixtures or equipment shall not be located in such a manner as to interfere with the normal operation of windows, doors or other means of egress openings.

[P] 2903.1.4 Water Closet Compartment

Each water closet utilized by the public or employees shall occupy a separate compartment with walls or partitions and a door enclosing the fixtures to ensure privacy.
Exceptions:
  1. Water closet compartments shall not be required in a single-occupant toilet room with a lockable door.
  2. Toilet rooms located in child day care facilities and containing two or more water closets shall be permitted to have one water closet without an enclosing compartment.
  3. This provision is not applicable to toilet areas located within Group I-3 housing areas.

[P] 2903.1.5 Urinal Partitions

Each urinal utilized by the public or employees shall occupy a separate area with walls or partitions to provide privacy. The horizontal dimension between walls or partitions at each urinal shall be not less than 30 inches (762 mm). The walls or partitions shall begin at a height not greater than 12 inches (305 mm) from and extend not less than 60 inches (1524 mm) above the finished floor surface. The walls or partitions shall extend from the wall surface at each side of the urinal not less than 18 inches (457 mm) or to a point not less than 6inches (152 mm) beyond the outermost front lip of the urinal measured from the finished backwall surface, whichever is greater.
Exceptions:
  1. Urinal partitions shall not be required in a single-occupant or family/assisted-use toilet room with a lockable door.
  2. Toilet rooms located in child day care facilities and containing two or more urinals shall be permitted to have one urinal without partitions.

Related Code Sections


(A) Wiring and Protection, Setting
maximum setting of the ground-fault protection shall be 1200 amperes, and the maximum time delay shall be one second for ground-fault currents equal ...
National Electrical Code 2017 of Illinois > 2 Wiring and Protection > 230 Services > 230.95 Ground-Fault Protection of Equipment > (A) Setting
(A) Wiring and Protection, Setting
maximum setting of the ground-fault protection shall be 1200 amperes, and the maximum time delay shall be one second for ground-fault currents equal ...
National Electrical Code 2020 of Illinois > 2 Wiring and Protection > 230 Services > 230.95 Ground-Fault Protection of Equipment > (A) Setting
2903.1 Plumbing Systems, Setting
Fixtures shall be set level and in proper alignment with reference to adjacent walls ...
Building Code 2021 of Illinois > 29 Plumbing Systems > 2903 Installation of Fixtures > 2903.1 Setting
(B) Special Conditions, Settings
by the PCS, the setting of the PCS controller shall be set within the ratings of that overcurrent device ...
National Electrical Code 2020 of Illinois > 7 Special Conditions > 705 Interconnected Electric Power Production Sources > 705.13 Power Control Systems > (B) Settings
(C) Equipment for General Use, Rating or Setting
A protective device that has a rating or setting not exceeding the value calculated according to the values given in Table 430.52 shall be used ...
National Electrical Code 2017 of Illinois > 4 Equipment for General Use > 430 Motors, Motor Circuits, and Controllers > 430.52 Rating or Setting for Individual Motor Circuit > (C) Rating or Setting
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING