In moderate hazard dry cleaning establishments, direct-fired dryers shall not be used. In low hazard dry cleaning establishments using nonflammable solvents only, direct fired dryers may be used, but such dryers shall not be located within twenty-five feet of a dry cleaning unit unless a noncombustible partition (which may be glazed), equipped with self-closing doors, is provided between the dry cleaning unit and the flame producing device. This partition may provide either complete or partial separation, provided that any partial separation shall be so arranged that the line of air travel around the partition from the cleaning units to the dryer is a minimum of twenty-five feet. Where a solid noncombustible partition is constructed extending to the ceiling and all portions of the enclosure are solid, except for self-closing access doors, and outdoor air for combustion and drying is supplied, the separation may be reduced to fifteen feet.

Related Code Sections

§27-431 Special Uses and Occupancies, Separation of Direct-Fired Dryers
In moderate hazard dry cleaning establishments, direct-fired dryers shall not be used. In low hazard dry cleaning establishments using nonflammable ...
Section 614 Specific Appliances, Clothes Dryer Exhaust
York City Building Code. Fire dampers shall not be installed in clothes dryer exhaust duct systems ...
Section 504 Exhaust Systems, Clothes Dryer Exhaust
dampers, combination fire/smoke dampers and any similar devices that will obstruct the exhaust flow, shall be prohibited in clothes dryer exhaust ducts ...
Section 504 Exhaust Systems, Clothes Dryer Exhaust
membrane, the annular space shall be sealed with noncombustible material, approved fire caulking or a noncombustible dryer exhaust duct wall receptacle ...
Section 504 Exhaust Systems, Clothes Dryer Exhaust
a wall or ceiling membrane, the annular space shall be sealed with noncombustible material, approved fire caulking or a noncombustible dryer exhaust duct ...