510.10 Separation of Different Tenancies
Go To Full Code Chapter
Spaces or dwelling units occupied by different tenants shall be separated by fire barriers having at least 1-hour fire-resistance ratings.
Exceptions:
Exceptions:
- Nonresidential spaces occupied by different tenants located in buildings that are sprinklered throughout.
- Tenant spaces in covered mall buildings complying with Section 402.