Sand and similar interceptors for every solid shall be so designed and located as to be readily accessible for cleaning, shall have a water seal of not less than 6 inches (152 mm), and shall be vented.
Upcodes Diagrams

Related Code Sections

1016.4 Traps and Interceptors, Separate Use
Sand and similar interceptors for every solid shall be so designed and located as to be readily accessible for cleaning, shall have a water seal ...
509.4.1 General Building Heights and Areas, Separation
Where Table 509 specifies a fire-resistance-rated separation, the incidental uses shall be separated from the remainder of the building by a fire ...
509.4.1 General Building Heights and Areas, Separation
Where Table 509.1 specifies a fire-resistance-rated separation, the incidental uses shall be separated from the remainder of the building by a fire ...