P-1506.2.1 Separate Test
Go To Full Code Chapter
The house drain and yard area drains, including all piping to a height of 2 feet above the
highest point of the house drain, shall be tested separately. All traps, pipe fittings and joints shall be exposed to
view when the test is made. Water shall be introduced into the system in the quantity deemed necessary by the
Department. To be approved, the flow of water through the system shall be unobstructed, and there shall be no
leakage through any pipe, joint, trap, or fitting.
Upcodes Diagrams
Related Code Sections
P-1506.2.1 Inspections and Tests, Separate Test
separately. All traps, pipe fittings and joints shall be exposed to
view when the test is made. Water shall be introduced into the system in the quantity ...
P-312.6.1 General Regulations, Separate Test
)
drain, shall be tested separately. All traps, pipe fittings and
joints shall be exposed to view when the test is made.
Water shall be introduced ...
5.2.1.2 Emergency Power Supply (EPS): Energy Sources, Converters, and Accessories,
load circuits shall be demonstrable by tests on separate prototype models, or by acceptable tests on the system components as performed ...
A9.3.2 Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations, Assembly U-Factors
then either a representative portion shall be tested or different portions shall be tested separately and a weighted average determined. To ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Philadelphia > Normative Appendix A Rated R-Value of Insulation and Assembly U-factor, C-Factor, and F-Factor Determinations > A9 Determination of Alternate Assembly U-Factors, C-Factors, F-Factors, or Heat Capacities > A9.3 Testing Procedures > A9.3.2 Assembly U-Factors