At the stations specified below, the transit easement required on a zoning lot shall constitute a volume whose dimensions above and below curb level shall comply with the requirements as set forth in Table A or Table B of this Section, depending on the depth of the proposed subway mezzanine below curb level, as established by the Metropolitan Transportation Authority.
Six possible types of transit easements are listed in Table A and in Table B. The applicant for a development or an enlargement involving ground level construction shall, in consultation with the Metropolitan Transportation Authority and the City Planning Commission, select the easement type that is most appropriate for the location.
MINIMUM DIMENSIONS FOR TRANSIT EASEMENT VOLUME (in feet)
Stations: Houston St., Kips Bay, Lenox Hill and E. 96th St.





Easement Type



Height above Curb Level (h)


Depth below Curb Level* (D)





Length (L)





Width(W)

Zoning Lots less than 10,000 sf


Zoning Lots 10,000 sf or more

1

15

20

80

20

x



2

15

30

80

20

x

x

3

15

30

85

32



x

4

15

25

80

10

x



5

15

30

80

10

x



6

15

25

60

20

x



* See Section 95—054



TABLE B
MINIMUM DIMENSIONS FOR TRANSIT EASEMENT VOLUME (in feet)
Stations: Chatham Square, Grand St., 14th St., 23rd St., UN Plaza, East Midtown and Yorkville






Easement Type



Height above Curb Level (h)


Depth below Curb Level* (D)





Length (L)





Width(W)

Zoning Lots less than 10,000 sf


Zoning Lots 10,000 sf or more

1

15

20

80

20

x



2

15

40

100

20

x

x

3

15

40

85

32



x

4

15

35

100

10

x



5

15

40

100

10

x



6

15

35

65

20

x



* See Section 95—054

Type 1 is appropriate on zoning lots of less than 10,000 square feet with adequate lot frontage and where the Metropolitan Transportation Authority provides final access to the subway mezzanine level under a public right-of-way.
(95-031.1)
Type 2 is appropriate on any size zoning lot for providing direct access to the subway mezzanine level by a "straight run" stairway and/or escalator.
(95-031.2)
Type 3 is applicable to zoning lots of 10,000 square feet or more for providing a "turn around" arrangement of stairs.
(95-031.3)
Types 4 and 5 are limited to zoning lots of less than 10,000 square feet with a narrow lot frontage for a single "straight-run" transit access facility, such as an escalator or stairway.


(95-031.4)




(95-031.5)

Type 6 is appropriate on zoning lots of less than 10,000 square feet for providing a "turn around" arrangement of stairs.
(95-031.6)
Where appropriate, any of these easement types may be used exclusively for light wells.

The Metropolitan Transportation Authority and the Commission, in consultation with the applicant, may make minor modifications of the dimensions of the easement volume type required on the applicant's site and the spacing of building columns permitted within the easement volume to facilitate the design and construction of circulation facilities appropriate for the area.
Upcodes Diagrams

Related Code Sections

Appendix A Selected Rules of the Department of Buildings [PDF] (page 36)
Rules and Regulations CHAPTER 15 FIRE PROTECTION §15-01 Communication and Alarm Systems ("Mini-Class 'E' Systems") for Certain Buildings under 100 ...
1024.2.4.3 Means of Egress, Transition
Where a wall-mounted demarcation line transitions to a floor-mounted demarcation line, or vice versa, the wall-mounted demarcation line shall drop ...
1025.2.4.3 Means of Egress, Transition
Where a wall-mounted demarcation line transitions to a floor-mounted demarcation line, or vice versa, the wall-mounted demarcation line shall drop ...
1029.10 Means of Egress, Transitions
Transitions between stairways and stepped aisles shall comply with either Section 1029.10.1 or 1029.10.2 ...