1926.102(c)(1) Selection of Shade Numbers for Welding Filter
Go To Full Code Chapter
Table E-1 shall be used as a guide for the selection of the proper shade numbers of filter lenses or plates used in welding. Shades more dense than those listed may be used to suit the individual's needs.
Welding operation | Shade number |
Shielded metal-arc welding 1/16-, 3/32-, 1/8-, 5/32-inch diameter electrodes |
10
|
Gas-shielded arc welding (nonferrous) 1/16-, 3/32-, 1/8-, 5/32-inch diameter electrodes |
11
|
Gas-shielded arc welding (ferrous) 1/16-, 3/32-, 1/8-, 5/32-inch diameter electrodes |
12
|
Shielded metal-arc welding 3/16-, 7/32-, 1/4-inch diameter electrodes |
12
|
5/16-, 3/8-inch diameter electrodes |
14
|
Atomic hydrogen welding |
10-14
|
Carbon-arc welding |
14
|
Soldering |
2
|
Torch brazing |
3 or 4
|
Light cutting, up to 1 inch |
3 or 4
|
Medium cutting, 1 inch to 6 inches |
4 or 5
|
Heavy cutting, over 6 inches |
5 or 6
|
Gas welding (light), up to 1/8-inch |
4 or 5
|
Gas welding (medium), 1/8-inch to 1/2-inch |
5 or 6
|
Gas welding (heavy), over 1/2-inch |
6 or 8
|
Upcodes Diagrams
Related Code Sections
1926.102(c)(1) Personal Protective and Life Saving Equipment, Selection of Shade Numbers for Welding Filter
Table E-1 shall be used as a guide for the selection of the proper shade numbers of filter lenses or plates used in welding. Shades more dense than ...
1926.60(i)(3) Occupational Health and Environmental Controls, Respirator Selection
Employers must: Select, and provide to employees ...
1926.1101(h)(3) Toxic and Hazardous Substances, Respirator Selection
, the appropriate respirators specified in paragraph (d)(3)(i)(A) of 29 CFR 1910.134; however, employers must not select or use filtering facepiece ...
1926.1127(g)(3) Toxic and Hazardous Substances, Respirator Selection
Employers must: Select, and provide to employees ...
1926.62(f)(3) Occupational Health and Environmental Controls, Respirator Selection
Employers must: Select, and provide to employees ...