// CODE SNIPPET
1810.3.13 Seismic Ties
Go To Full Code Chapter
Seismic ties shall comply with the provisions of ACI 318.
Exception: In Group R-3 and U occupancies of light-frame construction, deep foundation elements supporting foundation walls, isolated interior posts detailed so the element is not subject to lateral loads or exterior decks and patios are not subject to interconnection where the soils are of adequate stiffness, subject to the approval of the building official.
Related Code Sections
1810.3.13 Soils and Foundations, Seismic Ties
Seismic ties shall comply with the provisions of ACI 318. Exception: In Group R-3 and U occupancies of light-frame construction, deep foundation ...
1810.3.13 Soils and Foundations, Seismic Ties
For structures assigned to Seismic Design Category C, D, E or F, individual deep foundations shall be interconnected by ties. Unless it can ...
18.13.4 Earthquake-Resistant Structures, Foundation Seismic Ties
For structures assigned to SDC C, D, E, or F, individual pile caps, piers, or caissons shall be interconnected by foundation seismic ties ...
1809.13 Soils and Foundations, Footing Seismic Ties
Where a structure is assigned to Seismic Design Category D, E or F, individual spread footings founded on soil defined in Chapter 20 of ASCE 7 ...
1809.13 Soils and Foundations, Footing Seismic Ties
Where a structure is assigned to Seismic Design Category D, E or F, individual spread footings founded on soil defined in Chapter 20 of ASCE 7 ...