2205.2 Seismic Requirements for Structural Steel Structures

Jump To Full Code Chapter
The design of structural steel structures to resist seismic forces shall be in accordance with the provisions of Section 2205.2.1 or 2205.2.2, as applicable.
2205.2.1 Seismic Design Category B or C
Structural steel structures assigned to Seismic Design Category B or C shall be of any construction permitted in Section 2205. Where a response modification coefficient, R, in accordance with ASCE 7, Table 12.2-1 is used for the design of structural steel structures assigned to Seismic Design Category B or C, the structures shall be designed and detailed in accordance with the requirements of AISC 341.
Exception: The response modification coefficient, R, designated for "Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems" in ASCE 7, Table 12.2-1 shall be permitted for systems designed and detailed in accordance with AISC 360, and need not be designed and detailed in accordance with AISC 341.
2205.2.2 Seismic Design Category D, E or F
Structural steel structures assigned to Seismic Design Category D, E or F shall be designed and detailed in accordance with AISC 341, except as permitted in ASCE 7, Table 15.4-1.

Related Code Sections

2205.2 Steel, Seismic Requirements for Structural Steel Structures
The design of structural steel structures to resist seismic forces shall be in accordance with the provisions of Section 2205.2.1 or 2205.2.2 ...
1705.13.1 Special Inspections and Tests, Structural Steel
is not required for structural steel seismic force-resisting systems where the response modification coefficient, R, designated for "Steel systems ...
1705.13 Special Inspections and Tests, Testing for Seismic Resistance
to Seismic Design Category D, E, or F, nondestructive testing is not required for structural steel seismic force-resisting systems where design and detailing ...