• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2205.3 Seismic Requirements for Composite Construction

Building Code 2009 of Alabama > 22 Steel > 2205 Structural Steel > 2205.3 Seismic Requirements for Composite Construction
JUMP TO FULL CODE CHAPTER
The design, construction and quality of composite steel and concrete components that resist seismic forces shall conform to the requirements of the AISC 360 and ACI 318. An R factor as set forth in Section 12.2.1 of ASCE 7 for the appropriate composite steel and concrete system is permitted where the structure is designed and detailed in accordance with the provisions of AISC 341, Part II. In Seismic Design Category B or above, the design of such systems shall conform to the requirements of AISC 341, Part II.

2205.3.1 Seismic Design Categories D, E and F

Composite structures are permitted in Seismic Design Categories D , E and F, subject to the limitations in Section 12.2.1 of ASCE 7, where substantiating evidence is provided to demonstrate that the proposed system will perform as intended by AISC 341, Part II. The substantiating evidence shall be subject to building official approval. Where composite elements or connections are required to sustain inelastic deformations, the substantiating evidence shall be based on cyclic testing.

Related Code Sections


2205.3 Steel, Seismic Requirements for Composite Construction
The design, construction and quality of composite steel and concrete components that resist seismic forces shall conform to the requirements ...
Building Code 2009 of Alabama > 22 Steel > 2205 Structural Steel > 2205.3 Seismic Requirements for Composite Construction
2206.2.1 Steel, Seismic Requirements for Composite Structural Steel and Concrete Construction
compositely with reinforced concrete, the structures shall be designed and detailed in accordance with the requirements of AISC 341 ...
Building Code 2021 of Alabama > 22 Steel > 2206 Composite Structural Steel and Concrete Structures > 2206.2 Seismic Design > 2206.2.1 Seismic Requirements for Composite Structural Steel and Concrete Construction
2206.2.1 Steel, Seismic Requirements for Composite Structural Steel and Concrete Construction
compositely with reinforced concrete, the structures shall be designed and detailed in accordance with the requirements of AISC 341 ...
Building Code 2015 of Alabama > 22 Steel > 2206 Composite Structural Steel and Concrete Structures > 2206.2 Seismic Design > 2206.2.1 Seismic Requirements for Composite Structural Steel and Concrete Construction
2210.1 Steel, General
-steel structural members shall be in accordance with ASCE 8. Cold-formed steel light-frame construction shall comply with Section 2211. Where required ...
Building Code 2021 of Alabama > 22 Steel > 2210 Cold-Formed Steel > 2210.1 General
2210.1 Steel, General
required, the seismic design of cold-formed steel structures shall be in accordance with the additional provisions of Section 2210.2 ...
Building Code 2015 of Alabama > 22 Steel > 2210 Cold-Formed Steel > 2210.1 General
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING