2.21.2.6 Securing of Weights in Frames
Go To Full Code Chapter
The weights shall be mounted and secured in the frames to prevent shifting of the weights by an amount that will reduce the running clearances to less than those specified in 2.5.1.2.
Related Code Sections
2.21.2.6 Electric Elevators, Securing of Weights in Frames
The weights shall be mounted and secured in the frames to prevent shifting of the weights by an amount that will reduce the running clearances ...
2.11.12.2 Electric Elevators, Entrance Frames
The weight of the wall above the frame shall be supported by either of the following ...
5.3.1.14.1 Special Application Elevators, General Requirements
, whether carried in a frame or not, shall be fastened together and shall also be secured to prevent shifting by an amount that will reduce the running ...
410.36 Equipment for General Use, Means of Support
intervals. Luminaires shall be securely fastened to the ceiling framing member by mechanical means such as bolts, screws, or rivets. Listed clips ...
(D) Equipment for General Use, Secured
Cables, units, and panels shall be secured in place by frames or spreaders or other approved means while the masonry or asphalt finish is applied ...