// CODE SNIPPET
3510.5.2 Secured Location
JUMP TO FULL CODE CHAPTER
The microturbine shall be located in an area protected from unauthorized entry. Doors to rooms containing a microturbine shall be kept locked, but a key to such locks shall be readily available on the premises to certificate of fitness holders, maintenance personnel, and emergency responders.
Related Code Sections
1305.9.7 Fuel-Oil Piping and Storage, Movement and Vibration
The piping shall be located and secured from movement so as to prevent undue stress on the piping and to isolate the piping from vibrations from any ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.7 Movement and Vibration
1305.9.7 Fuel-Oil Piping and Storage, Movement and Vibration
The piping shall be located and secured from movement so as to prevent undue stress on the piping and to isolate the piping from vibrations from any ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.7 Movement and Vibration
1305.9.7 Fuel-Oil Piping and Storage, Movement and Vibration
The piping shall be located and secured from movement so as to prevent undue stress on the piping and to isolate the piping from vibrations from any ...
NYC Mechanical Code 2022 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Appliances or Storage Tanks Above Lowest Floor > 1305.9.7 Movement and Vibration
2205.6.4.1 Steel, Placing of Structural Members
During the placing of a structural member, the load shall not be released from the hoisting rope until the member is securely supported ...
NYC Building Code 2008 > 22 Steel > 2205 Structural Steel > 2205.6 Fabrication, Erection and Quality Control > 2205.6.4 Structural Steel Erection > 2205.6.4.1 Placing of Structural Members
3305.2.4 Safeguards During Construction or Demolition, Placing of Structural Members
be transferred from their place of storage directly to their permanent location and safely secured. No load shall be placed on open web steel joists until ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3305 Material Placement and Installation > 3305.2 Structural Steel Assembly > 3305.2.4 Placing of Structural Members