R702.3.5.1 Screw Fastening
JUMP TO FULL CODE CHAPTER
Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 and shall penetrate the wood not less than 5/8 inch (15.9 mm). Gypsum board and gypsum panel products shall be attached to cold-formed steel framing with minimum No. 6 screws. Screws for attaching gypsum board and gypsum panel products to cold-formed steel framing less than 0.033 inch (1 mm) thick shall be Type S in accordance with ASTM C1002 or bugle head style in accordance with ASTM C1513 and shall penetrate the steel not less than 3/8 inch (9.5 mm). Screws for attaching gypsum board and gypsum panel products to cold-formed steel framing 0.033 inch to 0.112 inch (1 mm to 3 mm) thick shall be in accordance with ASTM C954 or bugle head style in accordance with ASTM C1513. Screws for attaching gypsum board and gypsum panel products to structural insulated panels shall penetrate the wood structural panel facing not less than 7/16 inch (11.1 mm).
Related Code Sections
R702.3.5.1 Wall Covering, Screw Fastening
Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 and shall ...
Residential Code 2018 of Kansas > 7 Wall Covering > R702 Interior Covering > R702.3 Gypsum Board and Gypsum Panel Products > R702.3.5 Application > R702.3.5.1 Screw Fastening
E3908.15 Power and Lighting Distribution, Metal Boxes
or connection devices to boxes, such screws shall be one or more of the following: [250.148(C)] Machine screw-type fasteners that engage not less than ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3908 Grounding > E3908.15 Metal Boxes
R505.3.3.2 Floors, Joist Bottom Flange Bracing/Blocking
mils (0.84 mm) in thickness. Straps shall be fastened to the bottom flange of each joist with one No. 8 screw, fastened to blocking with two No. 8 screws ...
Residential Code 2018 of Kansas > 5 Floors > R505 Cold-Formed Steel Floor Framing > R505.3 Floor Construction > R505.3.3 Joist Bracing and Blocking > R505.3.3.2 Joist Bottom Flange Bracing/Blocking
(B) Wiring Methods and Materials, Substantial Construction
, or screws, such fasteners shall be spaced not more than 300 mm (12 in.) apart ...
National Electrical Code 2017 of Kansas > 3 Wiring Methods and Materials > 366 Auxiliary Gutters > 366.100 Construction > (B) Substantial Construction
(B) Wiring Methods and Materials, Substantial Construction
, or screws, such fasteners shall be spaced not more than 300 mm (12 in.) apart ...
National Electrical Code 2017 of Kansas > 3 Wiring Methods and Materials > 376 Metal Wireways > 376.100 Construction > (B) Substantial Construction