// CODE SNIPPET
R308.6.4 Screens With Multiple Glazing
Go To Full Code Chapter
Where the inboard pane is fully tempered, heat-strengthened or wired glass, a broken glass retention screen meeting the requirements of Section R308.6.7 shall be installed below the full area of the glass, except for Condition 1 or 2 listed in Section R308.6.5. Other panes in the multiple glazing shall be of any type listed in Section R308.6.2.
Upcodes Diagrams
Related Code Sections
R308.6.4 Building Planning, Screens With Multiple Glazing
Where the inboard pane is fully tempered, heat-strengthened or wired glass, a broken glass retention screen meeting the requirements of Section ...
2405.3 Glass and Glazing, Screening
noncorrosive screen materials shall be used. Heat-strengthened glass, fully tempered glass and wired glass, when used in multiple-layer glazing systems ...
2405.3 Glass and Glazing, Screening
, structurally equivalent noncorrosive screen materials shall be used. Annealed, heat-strengthened, fully tempered and wired glass, where used in multiple ...
2405.3 Glass and Glazing, Screening
monolithic and multiple-layer sloped glazing systems, the following applies:
Fully tempered glass installed without protective screens where glazed ...