The screen and its fastenings shall: be capable of supporting twice the weight of the glazing; be firmly and substantially fastened to the framing members; be installed within 4 inches (102 mm) of the glass, and have a mesh opening of not greater than 1 inch by 1 inch (25 mm by 25 mm).

Related Code Sections

R308.6.7 Building Planning, Screen Characteristics
The screen and its fastenings shall: be capable of supporting twice the weight of the glazing; be firmly and substantially fastened to the framing ...
2405.3 Glass and Glazing, Screening
Where used in monolithic glazing systems, heat-strengthened and fully tempered glass shall have screens installed below the glazing material. The ...
2405.3 Glass and Glazing, Screening
glass retention screens installed below the glazing material. The screens and their fastenings shall be: capable of supporting twice the weight ...
2405.3 Glass and Glazing, Screening
Where used in monolithic glazing systems, heat-strengthened and fully tempered glass shall have screens installed below the glazing material. The ...
511.1.5.1 Exhaust Systems, Screens
Where a screen is installed in a safety relief vent, the screen shall be attached so as to permit ready release under the explosion pressure ...