• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1001.3 Scope; Pressure Vessels; Labor and Industry

Minnesota Mechanical Code 2015 > 10 Boilers, Water Heaters and Pressure Vessels > 1001 General > 1001.3 Scope; Pressure Vessels; Labor and Industry
JUMP TO FULL CODE CHAPTER
The owner of a pressure vessel not specifically exempted by Minnesota Statutes, Section 326B.988, must ensure that the pressure vessel is inspected by an insurance company authorized to do business in the state or the Department of Labor and Industry at least every two years.

Exceptions: Pressure vessels identified in Minnesota Statutes, Section 326B.988, including the following, are not subject to this subpart:
  1. Pressure vessels in buildings occupied solely for residential purposes with accommodations for not more than five families.
  2. Pressure vessels under the direct jurisdiction of the United States.
  3. Pressure vessels located on farms used solely for agricultural or horticultural purposes; for the purposes of this section, boilers used for mint oil extraction are considered used for agricultural or horticultural purposes, provided that the owner or lessee complies with the inspection requirements contained in Minnesota Statutes, Section 326B.958.

Related Code Sections


1001.3 Boilers, Water Heaters and Pressure Vessels, Scope; Pressure Vessels; Labor and Industry
The owner of a pressure vessel not specifically exempted by Minnesota Statutes, Section 326B.988, must ensure that the pressure vessel is inspected ...
Minnesota Mechanical Code 2015 > 10 Boilers, Water Heaters and Pressure Vessels > 1001 General > 1001.3 Scope; Pressure Vessels; Labor and Industry
1006.6 Boilers, Water Heaters and Pressure Vessels, Safety and Relief Valve Discharge
and 5230.0990 on boilers, pressure vessels, and high-pressure piping under the jurisdiction of the Department of Labor and Industry, as applicable. Where a low ...
Minnesota Mechanical Code 2015 > 10 Boilers, Water Heaters and Pressure Vessels > 1006 Safety and Pressure Relief Valves and Controls > 1006.6 Safety and Relief Valve Discharge
1001.1 Boilers, Water Heaters and Pressure Vessels, Scope
This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels. Exceptions: Pressure ...
2020 Minnesota Mechanical Code > 10 Boilers, Water Heaters and Pressure Vessels > 1001 General > 1001.1 Scope
665.1 Special Equipment, Scope
and accessories for industrial and scientific applications. Medical or dental applications, appliances, or line frequency pipeline and vessel heating ...
National Electrical Code 2020 of Minnesota > 6 Special Equipment > 665 Induction and Dielectric Heating Equipment > 665.1 Scope
427.1 Equipment for General Use, Scope
This article covers electrically energized heating systems and the installation of these systems used with pipelines and vessels. Informational Note ...
National Electrical Code 2020 of Minnesota > 4 Equipment for General Use > 427 Fixed Electric Heating Equipment for Pipelines and Vessels > 427.1 Scope
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE