410.2.6 Scenery
Go To Full Code Chapter
Combustible materials used in sets and scenery shall meet the fire propagation performance criteria of Test Method 1 or Test Method 2, as appropriate, of NFPA 701, in accordance with Section 806 and the International Fire Code. Foam plastics and materials containing foam plastics shall comply with Section 2603 and the International Fire Code.
Related Code Sections
410.2.6 Special Detailed Requirements Based on Occupancy and Use, Scenery
Combustible materials used in sets and scenery shall meet the fire propagation performance criteria of Test Method 1 or Test Method 2, as appropriate ...
410.2.6 Special Detailed Requirements Based on Occupancy and Use, Scenery
Combustible materials used in sets and scenery shall meet the fire propagation performance criteria of Test Method 1 or Test Method 2, as appropriate ...
(A) Special Occupancies, Bracket Wiring
Brackets for use on scenery shall be wired internally, and the fixture stem shall be carried through to the back of the scenery where a bushing shall ...
(A) Special Occupancies, Bracket Wiring
Brackets for use on scenery shall be wired internally, and the fixture stem shall be carried through to the back of the scenery where a bushing shall ...
(A) Special Occupancies, General
that the flanges of the reflectors or other adequate guards protect the lamps from mechanical damage and from accidental contact with scenery or other ...