2.4.10.3.2 Scaling of Results
Go To Full Code Chapter
When the base shear for a given direction is less than that required by the equivalent lateral force procedure, the base shear shall be increased to the value prescribed in that procedure. All corresponding response parameters, including deflections, member forces and moments, shall be increased proportionately.
When the base shear for a given direction is greater than that required by the equivalent lateral force procedure, the base shear may be decreased to the value prescribed in that procedure. All corresponding response parameters, including deflections, member forces, and moments, may be decreased proportionately.
Related Code Sections
2.4.10.3.2 Seismic Evaluation Procedures for Hospital Buildings, Scaling of Results
When the base shear for a given direction is less than that required by the equivalent lateral force procedure, the base shear shall be increased ...
2.4.10.3.2 Seismic Evaluation Procedures for Hospital Buildings, Scaling of Results
When the base shear for a given direction is less than that required by the equivalent lateral force procedure, the base shear shall be increased ...
2.4.10.3.2 Seismic Evaluation Procedures for Hospital Buildings, Scaling of Results
When the base shear for a given direction is less than that required by the equivalent lateral force procedure, the base shear shall be increased ...
704.5 Fire and Smoke Protection Features, Truss Protection
The required thickness and construction of fire-resistance-rated assemblies enclosing trusses shall be based on the results of full-scale tests ...
704.5 Fire and Smoke Protection Features, Truss Protection
The required thickness and construction of fire-resistance-rated assemblies enclosing trusses shall be based on the results of full-scale tests ...