1910.217(h)(11) Safety System Certification/Validation
Go To Full Code Chapter
1910.217(h)(11)(i)
Prior to the initial use of any mechanical press in the PSDI mode, two sets of certification and validation are required:
1910.217(h)(11)(i)(A)
The design of the safety system required for the use of a press in the PSDI mode shall be certified and validated prior to installation. The manufacturer's certification shall be validated by an OSHA-recognized third-party validation organization to meet all applicable requirements of paragraphs (a) through (h) and appendix A of this section.
1910.217(h)(11)(i)(B)
After a press has been equipped with a safety system whose design has been certified and validated in accordance with paragraph (h)(11)(i) of this section, the safety system installation shall be certified by the employer, and then shall be validated by an OSHA-recognized third-party validation organization to meet all applicable requirements of paragraphs (a) through (h) and appendix A of this section.
1910.217(h)(11)(iii)
A label shall be affixed to the press as part of each installation certification/validation and the most recent recertification/revalidation. The label shall indicate the press serial number, the minimum safety distance (Ds) required by paragraph (h)(9)(v) of this section, the fulfillment of design certification/validation, the employer's signed certification, the identification of the OSHA-recognized third-party validation organization, its signed validation, and the date the certification/validation and recertification/revalidation are issued.
1910.217(h)(11)(iv)
Records of the installation certification and validation and the most recent recertification and revalidation shall be maintained for each safety system equipped press by the employer as long as the press is in use. The records shall include the manufacture and model number of each component and subsystem, the calculations of the safety distance as required by paragraph (h)(9)(v) of this section, and the stopping time measurements required by paragraph (h)(2)(ii) of this section. The most recent records shall be made available to OSHA upon request.
1910.217(h)(11)(v)
The employer shall notify the OSHA-recognized third-party validation organization within five days whenever a component or a subsystem of the safety system fails or modifications are made which may affect the safety of the system. The failure of a critical component shall necessitate the removal of the safety system from service until it is recertified and revalidated, except recertification by the employer without revalidation is permitted when a non-critical component or subsystem is replaced by one of the same manufacture and design as the original, or determined by the third-party validation organization to be equivalent by similarity analysis, as set forth in appendix A.
1910.217(h)(11)(vi)
The employer shall notify the OSHA-recognized third-party validation organization within five days of the occurrence of any point of operation injury while a press is used in the PSDI mode. This is in addition to the report of injury required by paragraph (g) of this section; however, a copy of that report may be used for this purpose.
1910.217(h)(11)(ii)
At least annually thereafter, the safety system on a mechanical power press used in the PSDI mode shall be recertified by the employer and revalidated by an OSHA-recognized third-party validation organization to meet all applicable requirements of paragraphs (a) through (h) and appendix A of this section. Any press whose safety system has not been recertified and revalidated within the preceding 12 months shall be removed from service in the PSDI mode until the safety system is recertified and revalidated.
Upcodes Diagrams
Related Code Sections
1910.217(h)(11) Machinery and Machine Guarding, Safety System Certification/Validation
and validated in accordance with paragraph (h)(11)(i) of this section, the safety system installation shall be certified by the employer ...
1910.217(h)(11)(ii) Machinery and Machine Guarding,
At least annually thereafter, the safety system on a mechanical power press used in the PSDI mode shall be recertified by the employer ...
1910.217(h)(11)(iv) Machinery and Machine Guarding,
Records of the installation certification and validation and the most recent recertification and revalidation shall be maintained for each safety ...
1910.217(h)(11)(vi) Machinery and Machine Guarding,
The employer shall notify the OSHA-recognized third-party validation organization within five days of the occurrence of any point of operation injury ...
1910.211(d)(65) Machinery and Machine Guarding, Validation
Validation or validate means for PSDI safety systems that an OSHA recognized third-party validation organization ...