• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 6107 Safety Precautions and Devices

Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6107 Safety Precautions and Devices
JUMP TO FULL CODE CHAPTER

6107.1 Safety Devices

Safety devices on LP-gas containers, equipment and systems shall not be tampered with or made ineffective.

6107.2 Smoking and Other Sources of Ignition

"No Smoking" signs complying with Section 310 shall be posted where required by the fire code official. Smoking within 25 feet (7620 mm) of a point of transfer, while filling operations are in progress at LP-gas containers or vehicles, shall be prohibited.
Control of other sources of ignition shall comply with Chapter 3 of this code and Section 6.25 of NFPA 58.

6107.3 Clearance to Combustibles

Weeds, grass, brush, trash and other combustible materials shall be kept not less than 10 feet (3048 mm) from LP-gas tanks or containers.

6107.4 Protecting Containers From Vehicles

Where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP-gas containers, regulators and piping shall be protected in accordance with NFPA 58.

Related Code Sections


Section 6107 Liquefied Petroleum Gases, Safety Precautions and Devices
Safety devices on LP-gas containers, equipment and systems shall not be tampered with or made ineffective ...
Fire Code 2021 of Colorado > 61 Liquefied Petroleum Gases > 6107 Safety Precautions and Devices
Section 6107 Liquefied Petroleum Gases, Safety Precautions and Devices
Safety devices on LP-gas containers, equipment and systems shall not be tampered with or made ineffective ...
Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6107 Safety Precautions and Devices
6107.3 Liquefied Petroleum Gases, Clearance to Combustibles
Weeds, grass, brush, trash and other combustible materials shall be kept not less than 10 feet (3048 mm) from LP-gas tanks or containers ...
Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6107 Safety Precautions and Devices > 6107.3 Clearance to Combustibles
6107.4 Liquefied Petroleum Gases, Protecting Containers From Vehicles
Where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP-gas containers, regulators and piping shall be protected ...
Fire Code 2021 of Colorado > 61 Liquefied Petroleum Gases > 6107 Safety Precautions and Devices > 6107.4 Protecting Containers From Vehicles
6107.4 Liquefied Petroleum Gases, Protecting Containers From Vehicles
Where exposed to vehicular damage due to proximity to alleys, driveways or parking areas, LP-gas containers, regulators and piping shall be protected ...
Fire Code 2018 of Colorado > 61 Liquefied Petroleum Gases > 6107 Safety Precautions and Devices > 6107.4 Protecting Containers From Vehicles
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING