In addition to the requirements of Section 2406.4, the following is considered a hazardous location and requires safety glazing: glazed panels within 48 inches (1219 mm) of a door, excluding transoms or vertical panels above 6 feet 8 inches (2031 mm).
453.13.7.1
All glazing in hazardous locations shall be safety glazing meeting the requirements of the Florida Building Code, Building, Section 2406.
453.13.7.2
Large glass panels shall be subdivided by a built-in horizontal member or a permanent chair rail not less than 11/2 inches (38 mm) in width, located between 24 and 36 inches (610 and 914 mm) above the floor.
Upcodes Diagrams

Related Code Sections

Section 2406 Glass and Glazing, Safety Glazing
2406.1.4. Exception: Mirrors and other glass panels mounted or hung on a surface that provides a continuous backing support ...