1907.4.2 Rust or Mill Scale
Go To Full Code Chapter
Except for prestressing reinforcement, steel reinforcement with rust, mill scale or a combination of both, shall be permitted, provided the minimum dimensions, including height of deformations and weight of a hand-wire-brushed test specimen, comply with applicable ASTM specifications specified in Section 1903.6.
Related Code Sections
1907.4.2 Concrete, Rust or Mill Scale
Except for prestressing reinforcement, steel reinforcement with rust, mill scale or a combination of both, shall be permitted, provided the minimum ...
1907.4.2 Concrete, Rust or Mill Scale
Except for prestressing steel, steel reinforcement with rust, mill scale or a combination of both, shall be permitted, provided the minimum ...
1907.4.2 Concrete, Rust or Mill Scale
Except for prestressing steel, steel reinforcement with rust, mill scale or a combination of both, shall be permitted, provided the minimum ...
26.6.1.2 Construction Documents and Inspection,
Compliance requirements: (a) Mill test reports for reinforcement shall be submitted. (b) Nonprestressed reinforcement with rust, mill scale ...
Section 1907 Concrete, Details of Reinforcement
reinforcement, steel reinforcement with rust, mill scale or a combination of both, shall be permitted, provided the minimum dimensions, including ...