• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1805.5.1.3 Rubble Stone

2010 Building Code of NY > 18 Soils and Foundations > 1805 Footings and Foundations > 1805.5 Foundation Walls > 1805.5.1 Foundation Wall Thickness > 1805.5.1.3 Rubble Stone
JUMP TO FULL CODE CHAPTER
Foundation walls of rough or random rubble stone shall not be less than 16 inches (406 mm) thick. Rubble stone shall not be used for foundations for structures in Seismic Design Category C, D, E or F.

Related Code Sections


1805.5.1.3 Soils and Foundations, Rubble Stone
Foundation walls of rough or random rubble stone shall not be less than 16 inches (406 mm) thick. Rubble stone shall not be used for foundations ...
2010 Building Code of NY > 18 Soils and Foundations > 1805 Footings and Foundations > 1805.5 Foundation Walls > 1805.5.1 Foundation Wall Thickness > 1805.5.1.3 Rubble Stone
2109.5.2.2 Masonry, Rubble Stone Walls
The minimum thickness of rough, random or coursed rubble stone walls shall be 16 inches (406 mm) ...
2010 Building Code of NY > 21 Masonry > 2109 Empirical Design of Masonry > 2109.5 Thickness of Masonry > 2109.5.2 Minimum Thickness > 2109.5.2.2 Rubble Stone Walls
R404.1.8 Foundations, Rubble Stone Masonry
Rubble stone masonry foundation walls shall have a minimum thickness of 16 inches (406 mm), shall not support an unbalanced backfill exceeding 8 feet ...
Residential Code 2015 of New York State > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.8 Rubble Stone Masonry
R404.1.8 Foundations, Rubble Stone Masonry
Rubble stone masonry foundation walls shall have a minimum thickness of 16 inches (406 mm), shall not support an unbalanced backfill exceeding 8 feet ...
2020 Residential Code of New York State > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.8 Rubble Stone Masonry
R404.1.8 Foundations, Rubble Stone Masonry
Rubble stone masonry foundation walls shall have a minimum thickness of 16 inches (406 mm), shall not support an unbalanced backfill exceeding 8 feet ...
2010 Residential Code of NY > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.8 Rubble Stone Masonry
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE