§27-454 Roof Storage of Motor Vehicles
Go To Full Code Chapter
Roofs of buildings shall not be used for the parking or storage of motor vehicles unless the building is of class I-A, I-B, or I-C construction, or is an open parking structure. When the roof of a building is used for parking of motor vehicles, it shall be provided with a parapet wall or guard rail at least three feet six inches high, and with curbs or wheel guards of noncombustible materials of a least eight inches high. Such guards shall be substantially anchored to prevent any vehicle from striking the parapet wall or guard rail. Guard rails shall comply with the requirements for railings in subchapter nine of this chapter.
Related Code Sections
§27-454 Special Uses and Occupancies, Roof Storage of Motor Vehicles
Roofs of buildings shall not be used for the parking or storage of motor vehicles unless the building is of class I-A, I-B, or I-C construction ...
20.2* Special Designs of Storage Protection, Plastic Motor Vehicle Components
Commodity Maximum Storage Height Maximum Ceiling/Roof Height Type of System Maximum Sprinkler Spacingb Number of Design Sprinklers by Minimum ...
406.5 Special Detailed Requirements Based on Use and Occupancy, Motor Fuel-Dispensing Facilities
in canopies erected over motor vehicle fuel-dispensing station fuel dispensers, provided the panels are located at least 10 feet (3048 mm) from any ...
406.7 Special Detailed Requirements Based on Use and Occupancy, Motor Fuel-Dispensing Facilities
to be installed in canopies erected over motor vehicle fuel-dispensing station fuel dispensers, provided the panels are located not less than 10 feet ...
Section 406 Special Detailed Requirements Based on Use and Occupancy, Motor Vehicle-Related Occupancies
on at least two sides and unenclosed for at least 50 percent of perimeter, used for the parking or storage of passenger motor vehicles. Such facility ...