Open vent pipes that extend through a roof that do not meet the conditions of Section P3103.1.2 or P3103.1.3 shall terminate not less than 6 inches (150 mm) above the roof or 6 inches (150 mm) above the anticipated snow accumulation, whichever is greater.
Upcodes Diagrams

Related Code Sections

903.1 Vents, Roof Extension
All open vent pipes that extend through a roof shall be terminated at least 6 inches above the roof, except that where a roof is to be used for any ...
P3103.1.1 Vents, Roof Extension
Open vent pipes that extend through a roof that do not meet the conditions of Section P3103.1.2 or P3103.1.3 shall terminate not less than 6 inches ...
P3103.1.1 Vents, Roof Extension
Open vent pipes that extend through a roof that do not meet the conditions of Section P3103.1.2 or P3103.1.3 shall terminate not less than 6 inches ...