Roofs shall be without concealed spaces or with concealed spaces complying with Section 602.4.4.3. Roof decks shall be constructed in accordance with Section 2304.11.4.1 or 2304.11.4.2. Other types of decking shall be an alternative that provides equivalent fire resistance and structural properties. Where supported by a wall, roof decks shall be anchored to walls to resist forces determined in accordance with Chapter 16. Such anchors shall consist of steel bolts, lags, screws or approved hardware of sufficient strength to resist prescribed forces.
2304.11.4.1 Cross-Laminated Timber Roofs
Cross-laminated timber roofs shall be not less than 3 inches (76 mm) nominal in thickness and shall be continuous from support to support and mechanically fastened to one another.
2304.11.4.2 Sawn, Wood Structural Panel, or Glued-Laminated Plank Roofs
Sawn, wood structural panel, or glued-laminated plank roofs shall be one of the following:
  1. Sawn or glued laminated, splined or tongue-and-groove plank, not less than 2 inches (51 mm) nominal in thickness.
  2. 11/8-inch-thick (32 mm) wood structural panel (exterior glue).
  3. Planks not less than 3 inches (76 mm) nominal in width, set on edge close together and laid as required for floors.
Upcodes Diagrams

Related Code Sections

1609.5.1 Structural Design, Roof Deck
The roof deck shall be designed to withstand the wind pressures determined in accordance with ASCE 7 ...
1609.5.1 Structural Design, Roof Deck
The roof deck shall be designed to withstand the wind pressures determined in accordance with ASCE 7 ...
2304.11.4 Wood, Roof Decks
Roofs shall be without concealed spaces and roof decks shall be constructed in accordance with Section 2304.11.4.1 or 2304.11.4.2. Other types ...
2304.11.4 Wood, Roof Decks
Roofs shall be without concealed spaces or with concealed spaces complying with Section 602.4.4.3. Roof decks shall be constructed in accordance ...
2210.1.1.2 Steel, Steel Roof Deck
Steel roof decks shall be permitted to be designed and constructed in accordance with ANSI/SDI-RD1.0 ...