Section R902 Roof Classification
Go To Full Code Chapter
R902.1 Roofing Covering Materials
Roofs shall be covered with materials as set forth in Sections R904 and R905. Class A, B or C roofing shall be installed in areas designated by law as requiring their use or when the edge of the roof is less than 3 feet (914 mm) from a lot line. Classes A, B and C roofing required by this section to be listed shall be tested in accordance with UL 790 or ASTM E 108.
Exceptions:
- Class A roof assemblies include those with coverings of brick, masonry and exposed concrete roof deck.
- Class A roof assemblies also include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile, or slate installed on noncombustible decks.
- Class A roof assemblies include minimum 16 oz/ft2 copper sheets installed over combustible decks.
R902.2 Fire-Retardant-Treated Shingles and Shakes
Fire-retardant-treated wood shakes and shingles shall be treated by impregnation with chemicals by the full-cell vacuum-pressure process, in accordance with AWPA C1. Each bundle shall be marked to identify the manufactured unit and the manufacturer, and shall also be labeled to identify the classification of the material in accordance with the testing required in Section R902.1, the treating company and the quality control agency.
Upcodes Diagrams
Related Code Sections
Section R902 Roof Assemblies, Roof Classification
Roofs shall be covered with materials as set forth in Sections R904 and R905. Class A, B or C roofing shall be installed in areas designated by law ...
R902.1 Roof Assemblies, Roofing Covering Materials
Roofs shall be covered with materials as set forth in Sections R904 and R905. Class A, B or C roofing shall be installed in jurisdictions designated ...
108.3 Scope and Administration, Site Plan
classification of buildings, types of ignition-resistant construction of buildings, structures and their appendages, roof classification of buildings and site ...
108.3 Scope and Administration, Site Plan
classification of buildings, types of ignition-resistant construction of buildings, structures and their appendages, roof classification of buildings and site ...
1509.7.2 Roof Assemblies and Rooftop Structures, Fire Classification
Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505 ...