• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R602.7.2 Rim Board Headers

Residential Code 2021 of Colorado > 6 Wall Construction > R602 Wood Wall Framing > R602.7 Headers > R602.7.2 Rim Board Headers
JUMP TO FULL CODE CHAPTER
Rim board header size, material and span shall be in accordance with Table R602.7(1). Rim board headers shall be constructed in accordance with Figure R602.7.2 and shall be supported at each end by full-height studs. The number of full-height studs at each end shall be not less than the number of studs displaced by half of the header span based on the maximum stud spacing in accordance with Table R602.3(5). Rim board headers supporting concentrated loads shall be designed in accordance with accepted engineering practice.




For SI: 25.4 mm = 1 inch.
FIGURE R602.7.2
RIM BOARD HEADER CONSTRUCTION

Related Code Sections


R602.7.2 Wall Construction, Rim Board Headers
Rim board header size, material and span shall be in accordance with Table R602.7(1). Rim board headers shall be constructed in accordance ...
Residential Code 2021 of Colorado > 6 Wall Construction > R602 Wood Wall Framing > R602.7 Headers > R602.7.2 Rim Board Headers
2303.1.13 Wood, Engineered Wood Rim Board
Engineered wood rim boards shall conform to ANSI/APA PRR 410 or shall be evaluated in accordance with ASTM D7672. Structural capacities shall ...
Building Code 2021 of Colorado > 23 Wood > 2303 Minimum Standards and Quality > 2303.1 General > 2303.1.13 Engineered Wood Rim Board
2303.1.13 Wood, Engineered Wood Rim Board
Engineered wood rim boards shall conform to ANSI/APA PRR 410 or shall be evaluated in accordance with ASTM D7672. Structural capacities shall ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 23 Wood > 2303 Minimum Standards and Quality > 2303.1 General > 2303.1.13 Engineered Wood Rim Board
2303.1.13 Wood, Engineered Wood Rim Board
Engineered wood rim boards shall conform to ANSI/APA PRR 410 or shall be evaluated in accordance with ASTM D7672. Structural capacities shall ...
Building Code of the Department of Personnel & Administration/Office of the State Architect (DPA/OSA) > 23 Wood > 2303 Minimum Standards and Quality > 2303.1 General > 2303.1.13 Engineered Wood Rim Board
R502.1.7 Floors, Engineered Wood Rim Board
Engineered wood rim boards shall conform to ANSI/APA PRR 410 or shall be evaluated in accordance with ASTM D7672. Structural capacities shall ...
Residential Code 2021 of Colorado > 5 Floors > R502 Wood Floor Framing > R502.1 General > R502.1.7 Engineered Wood Rim Board
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING